Atomic Absorption Spectrometry Laboratory Course

Operate flame and graphite-furnace AAS methods with controlled calibration, quality assurance and systematic fault diagnosis.
Atomic Absorption Spectrometry Laboratory Course

At a glance

Duration
1 Week
Format
Classroom
Cities
London, Jakarta, Nice, Marbella, Vienna, Tashkent and more
Next session
9 – 13 November 2026, London
Average fee
7,500 €

Overview

Atomic Absorption Spectrometry Laboratory Practice Course is a one-week course for laboratory analysts, chemists, quality-control specialists and environmental testing personnel who leave with an AAS Method Control File. Participants apply flame and graphite-furnace workflows to sample preparation, calibration, interference control, quality assurance, maintenance, troubleshooting and defensible reporting across environmental and process laboratories. The course separates element-specific absorbance practice from plasma emission methods. Agile Leaders Training Center develops practical atomic absorption laboratory capability.

Who Should Attend

  • Laboratory teams responsible for elemental analysis and result release
  • Quality teams responsible for calibration controls and analytical records
  • Environmental testing teams responsible for water, waste and soil extracts
  • Process laboratory teams responsible for raw-material and product checks
  • Technical support teams responsible for instrument availability and fault isolation

The course assumes participants already perform routine wet-chemistry work and leaves out ICP-OES method development and advanced research instrumentation.

Departments and Industries

The course supports laboratory and quality functions working with elemental measurements in several sectors.

  • Environmental monitoring and water treatment laboratories
  • Oil, gas and petrochemical process laboratories
  • Mining, metals and materials testing departments
  • Food, pharmaceutical and consumer-product quality laboratories
  • Maintenance and technical assurance teams supporting analytical instruments

Learning Objectives

By the end of this course, participants will be able to:

  • Compare flame and graphite-furnace AAS method capabilities
  • Apply sample preparation and contamination-control practices
  • Build calibration and quality-control sequences
  • Analyze chemical, spectral and background interference evidence
  • Diagnose sensitivity, drift and precision faults
  • Evaluate results and assemble defensible analytical records

Course Agenda

Day 1: AAS Measurement Foundations

  • Beer-Lambert Absorbance Model and Element-Specific Line Sources
  • Hollow-Cathode Lamp Selection and Optical Alignment Checks
  • Flame AAS and Graphite-Furnace AAS Decision Matrix
  • EPA Method 7000B and Method 7010 Scope Mapping
  • AAS Method Control File Structure and Data-Quality Objectives

Day 2: Samples, Standards and Calibration

  • Sample Preservation, Digestion and Dilution Decision Tree
  • Volumetric Standard Preparation and Traceability Record
  • Blank, Calibration Standard and Continuing Check Sequence
  • Calibration Curve Review and Working-Range Evaluation
  • Contamination Control and Laboratory Reagent-Water Checklist

Day 3: Atomization and Interference Control

  • Burner, Nebulizer and Spray-Chamber Optimization Method
  • Graphite-Furnace Temperature Program Development
  • Background Correction and Nonspecific Absorption Assessment
  • Chemical, Ionization and Spectral Interference Diagnosis Matrix
  • Matrix Modification and Standard-Addition Selection Rules

Day 4: Quality Assurance and Troubleshooting

  • Method Blank, Spike, Duplicate and Control-Sample Plan
  • Detection Limit and Quantitation Limit Evaluation Workflow
  • Control Chart Review and Out-of-Control Response Rules
  • Sensitivity, Drift and Precision Fault-Finding Tree
  • Preventive Maintenance Log and Corrective-Action Record

Day 5: Laboratory Practice and Capstone

  • Exercise: Select FAAS or GFAAS for a Matrix-and-Level Scenario
  • Exercise: Build a Calibration and Quality-Control Batch
  • Exercise: Diagnose Interference and Instrument-Fault Evidence
  • Exercise: Review Results Against Acceptance Criteria
  • Capstone Exercise: Complete an AAS Method Control File

Practical Exercises

The course uses suggested activities that connect method decisions with laboratory evidence.

  • Suggested activity: map a water and process-sample workflow from receipt through reporting
  • Suggested activity: prepare a calibration sequence with blanks, checks, spikes and duplicates
  • Suggested activity: investigate poor sensitivity using maintenance and interference evidence
  • Suggested activity: assemble an AAS Method Control File for technical review

FAQs

Who suits the Atomic Absorption Spectrometry Laboratory Practice Course?

Laboratory analysts, chemists and quality personnel suit the course when they already perform routine laboratory calculations and safe wet-chemistry tasks.

How does atomic absorption spectrometry differ from ICP-OES training?

Atomic absorption spectrometry uses element-specific absorption measurements and flame or furnace atomization, while ICP-OES training centers on plasma emission and multielement optical systems.

Does atomic absorption training cover both flame and graphite-furnace methods?

Yes. The course compares method selection, operating controls, sensitivity, interferences and quality practices for flame and graphite-furnace AAS.

How does atomic absorption quality control support defensible results?

Atomic absorption quality control links blanks, calibration checks, spikes, duplicates and control samples to documented acceptance decisions and corrective actions.

What atomic absorption troubleshooting skills are practiced?

Participants practice diagnosing sensitivity loss, drift, poor precision, contamination, background effects, matrix interference and component-related faults.

Conclusion

Participants complete an AAS Method Control File that links method choice, preparation, calibration, quality controls and troubleshooting evidence. The file supports consistent batch review and clearer corrective-action decisions. Participants can adapt its templates to environmental, process and product-testing matrices under their laboratory procedures.

credits: 5 credit per day

Course Mode: full-time

Provider: Agile Leaders Training Center

Showing 1-20 of 58 events
Image Location Dates Duration Mode Price Actions
London London Week 46, 2026
9 – 13 November 2026
1 Week Onsite €6,500
Jakarta Jakarta Week 46, 2026
9 – 13 November 2026
1 Week Onsite €8,000
Nice Nice Week 47, 2026
16 – 20 November 2026
1 Week Onsite €8,000
Marbella Marbella Week 47, 2026
22 – 26 November 2026
1 Week Onsite €6,500
Vienna Vienna Week 49, 2026
30 November – 4 December 2026
1 Week Onsite €7,500
Tashkent Tashkent Week 49, 2026
6 – 10 December 2026
1 Week Onsite €8,000
Amsterdam Amsterdam Week 51, 2026
14 – 18 December 2026
1 Week Onsite €6,500
Bangkok Bangkok Week 51, 2026
20 – 24 December 2026
1 Week Onsite €8,000
Abu Dhabi Abu Dhabi Week 53, 2026
28 December 2026 – 1 January 2027
1 Week Onsite €6,500
Abu Dhabi Abu Dhabi Week 01, 2027
4 – 8 January 2027
1 Week Onsite €6,500
Doha Doha Week 01, 2027
10 – 14 January 2027
1 Week Onsite €7,000
Berlin Berlin Week 03, 2027
18 – 22 January 2027
1 Week Onsite €6,500
Cape town Cape town Week 03, 2027
24 – 28 January 2027
1 Week Onsite €6,000
Lagos Lagos Week 04, 2027
31 January – 4 February 2027
1 Week Onsite €6,000
Kuala Lumpur Kuala Lumpur Week 05, 2027
1 – 5 February 2027
1 Week Onsite €6,500
Tokyo Tokyo Week 07, 2027
15 – 19 February 2027
1 Week Onsite €12,000
New York New York Week 08, 2027
22 – 26 February 2027
1 Week Onsite €16,000
Kuwait Kuwait Week 08, 2027
28 February – 4 March 2027
1 Week Onsite €7,000
Nairobi Nairobi Week 09, 2027
7 – 11 March 2027
1 Week Onsite €6,000
Tbilisi Tbilisi Week 11, 2027
15 – 19 March 2027
1 Week Onsite €5,700

Frequently asked questions

What does this course cover?

OverviewAtomic Absorption Spectrometry Laboratory Practice Course is a one-week course for laboratory analysts, chemists, quality-control specialists and environmental testing personnel who leave with an AAS Method Control File. Participants apply flame and graphite-furnace workflows to sample preparation, calibration, interference control, quality assura…

Are training dates available?

Yes. Available dates and destinations are listed in the course dates section on this page.

How can I register?

Choose an available date on this page and complete the registration form, or send a programme enquiry.

Can I download the course brochure?

Yes. Use the brochure download link provided on this page.

This course by city