Straton UPS Level 2 Maintenance and Troubleshooting Course

Advanced diagnostic practice for experienced teams maintaining Straton industrial UPS systems and critical-power continuity.
Straton UPS Level 2 Maintenance and Troubleshooting Course

At a glance

Duration
1 Week
Format
Classroom
Cities
Vienna, Jakarta, Nairobi, Tashkent, Dubai, Bali and more
Next session
30 November – 4 December 2026, Vienna
Average fee
7,500 €

Overview

Straton UPS Level 2 Maintenance and Troubleshooting Training Course is a one-week advanced course for UPS service, electrical maintenance, critical-power, and facilities functions who leave with a Straton UPS Level 2 Maintenance and Troubleshooting Plan. The course connects industrial UPS architecture, safe maintenance boundaries, diagnostic evidence, alarm analysis, fault isolation, controlled replacement, and performance verification. Participants practice maintenance decisions through documented scenarios rather than live intrusive work. Agile Leaders Training Center delivers this course on Straton UPS Level 2 maintenance and troubleshooting.

Who Should Attend

  • Functions responsible for servicing industrial UPS equipment and maintaining power continuity
  • Teams responsible for electrical maintenance, inspection, calibration, and controlled component replacement
  • Groups responsible for critical-power monitoring, alarm response, and fault escalation
  • Personnel responsible for facilities resilience, maintenance planning, and contractor oversight
  • Specialists responsible for battery condition, thermal evidence, and UPS performance testing

The course assumes participants already interpret UPS one-line diagrams, operating states, alarms, isolation controls, and Level 1 maintenance records, and leaves out introductory electrical theory, live intrusive work, proprietary software access, firmware changes, and unsupported model-specific repair procedures.

Departments and Industries

The course supports departments and industries that depend on governed industrial UPS maintenance and critical-power continuity.

  • Electrical maintenance and reliability departments
  • Facilities engineering and critical-environment operations
  • Data centers, telecommunications, and control rooms
  • Process industries, utilities, and manufacturing facilities
  • Hospitals, laboratories, and transport infrastructure

Learning Objectives

By the end of this course, participants will be able to:

  • Analyze Straton UPS architecture and safe maintenance boundaries.
  • Diagnose rectifier, inverter, bypass, battery, and cooling evidence.
  • Use alarm histories to isolate probable fault paths.
  • Evaluate inspection, calibration, and replacement decisions.
  • Apply functional tests and performance verification criteria.
  • Build a preventive maintenance and escalation plan.

Course Agenda

Day 1: Establish Safe Diagnostic Boundaries

  • Straton Industrial UPS Functional Architecture Map
  • Rectifier, Inverter, Static Bypass, and Battery Energy-Flow Model
  • IEC 62040-1 Safety Boundary and Backfeed Checklist
  • Maintenance State, Isolation, and Escalation Decision Matrix
  • Level 1 Record-to-Level 2 Evidence Handover Template

Day 2: Evaluate Power Conversion Subsystems

  • Rectifier and Charger Input Evidence Worksheet
  • DC Link Condition and Measurement Review Method
  • Inverter Output Waveform and Load Evidence Matrix
  • Static and Manual Bypass State-Transition Diagram
  • Cooling Path, Fan, Filter, and Thermal Inspection Checklist

Day 3: Isolate Alarms and Fault Paths

  • Alarm Chronology and Event-Log Reconstruction Sheet
  • Symptom-to-Subsystem Fault Isolation Tree
  • Overload, Voltage, and Frequency Evidence Comparator
  • Intermittent Fault Reproduction and Exclusion Method
  • Diagnostic Finding, Uncertainty, and Escalation Record

Day 4: Plan Maintenance and Verify Performance

  • IEEE 1188-2025 VRLA Battery Condition Review
  • Inspection, Calibration, and Controlled Replacement Decision Board
  • IEC 62040-3 Functional Performance Test Matrix
  • Load, Efficiency, and Transfer-Performance Verification Sheet
  • Preventive and Predictive Maintenance Interval Planner

Day 5: Practice Integrated Troubleshooting

  • Suggested Exercise: Reconstruct a Straton UPS Alarm Sequence
  • Suggested Exercise: Isolate a Power Conversion Fault Path
  • Suggested Exercise: Evaluate Battery and Thermal Evidence
  • Suggested Exercise: Verify Post-Maintenance Functional Performance
  • Capstone Exercise: Build the Straton UPS Level 2 Maintenance and Troubleshooting Plan

Practical Exercises

The course uses suggested activities to convert UPS evidence into controlled maintenance and escalation decisions.

  • Suggested activity: trace rectifier, inverter, bypass, battery, and cooling evidence through an industrial UPS scenario.
  • Suggested activity: rebuild an alarm timeline and distinguish probable causes from secondary effects.
  • Suggested activity: compare calibration, component replacement, further testing, and escalation options against documented boundaries.
  • Suggested activity: assemble performance checks and maintenance intervals into a reviewable plan.

FAQs

Who suits Straton UPS Level 2 maintenance training, and what does it assume?

Straton UPS Level 2 maintenance training suits experienced UPS service, electrical maintenance, critical-power, and facilities personnel who already use diagrams, operating records, alarms, isolation controls, and Level 1 maintenance evidence.

How does Straton UPS Level 2 troubleshooting differ from basic UPS operations training?

Straton UPS Level 2 troubleshooting moves beyond normal operating checks into subsystem evidence, alarm chronology, fault isolation, maintenance decisions, performance verification, and defined escalation boundaries.

How should Straton UPS alarms be analyzed during maintenance?

Straton UPS alarms should be ordered by time, operating state, load condition, subsystem, preceding event, and secondary effect before a probable fault path is selected and tested against available evidence.

What evidence supports a Straton UPS component replacement decision?

A Straton UPS component replacement decision needs repeatable symptoms, measurements, inspection findings, alarm history, isolation results, applicable limits, safety boundaries, and a defined post-maintenance verification method.

How is Straton UPS performance verified after maintenance?

Straton UPS performance is verified through controlled functional checks covering operating modes, transfers, alarms, load behavior, output characteristics, battery evidence, thermal condition, and documented acceptance or escalation criteria.

Conclusion

Participants take back a Straton UPS Level 2 Maintenance and Troubleshooting Plan. The plan joins architecture, safety boundaries, subsystem evidence, alarms, fault paths, battery and thermal condition, maintenance decisions, tests, and escalation criteria. It changes scattered observations into a traceable basis for preventive work, controlled intervention, post-maintenance verification, and technical escalation.

credits: 5 credit per day

Course Mode: full-time

Provider: Agile Leaders Training Center

Showing 21-40 of 58 events
Image Location Dates Duration Mode Price Actions
Abu Dhabi Abu Dhabi Week 12, 2027
22 – 26 March 2027
1 Week Onsite €6,500
Lisbon Lisbon Week 13, 2027
29 March – 2 April 2027
1 Week Onsite €6,500
Dubai Dubai Week 15, 2027
12 – 16 April 2027
1 Week Onsite €6,500
London London Week 16, 2027
19 – 23 April 2027
1 Week Onsite €6,500
Doha Doha Week 16, 2027
25 – 29 April 2027
1 Week Onsite €7,000
Rome Rome Week 18, 2027
3 – 7 May 2027
1 Week Onsite €6,500
Casablanca Casablanca Week 19, 2027
10 – 14 May 2027
1 Week Onsite €6,000
Berlin Berlin Week 19, 2027
10 – 14 May 2027
1 Week Onsite €6,500
Sharm El-Sheikh Sharm El-Sheikh Week 20, 2027
17 – 21 May 2027
1 Week Onsite €5,200
Marbella Marbella Week 20, 2027
23 – 27 May 2027
1 Week Onsite €6,500
Madrid Madrid Week 21, 2027
24 – 28 May 2027
1 Week Onsite €6,500
Toronto Toronto Week 21, 2027
30 May – 3 June 2027
1 Week Onsite €16,000
San Diego San Diego Week 23, 2027
7 – 11 June 2027
1 Week Onsite €16,000
Phuket Phuket Week 23, 2027
13 – 17 June 2027
1 Week Onsite €8,000
Singapore Singapore Week 24, 2027
14 – 18 June 2027
1 Week Onsite €6,500
Trabzon Trabzon Week 24, 2027
20 – 24 June 2027
1 Week Onsite €8,000
Amsterdam Amsterdam Week 26, 2027
28 June – 2 July 2027
1 Week Onsite €6,500
Muscat Muscat Week 27, 2027
11 – 15 July 2027
1 Week Onsite €6,500
Tokyo Tokyo Week 28, 2027
12 – 16 July 2027
1 Week Onsite €12,000
Manama Manama Week 29, 2027
25 – 29 July 2027
1 Week Onsite €6,500

Frequently asked questions

What does this course cover?

OverviewStraton UPS Level 2 Maintenance and Troubleshooting Training Course is a one-week advanced course for UPS service, electrical maintenance, critical-power, and facilities functions who leave with a Straton UPS Level 2 Maintenance and Troubleshooting Plan. The course connects industrial UPS architecture, safe maintenance boundaries, diagnostic evide…

Are training dates available?

Yes. Available dates and destinations are listed in the course dates section on this page.

How can I register?

Choose an available date on this page and complete the registration form, or send a programme enquiry.

Can I download the course brochure?

Yes. Use the brochure download link provided on this page.

This course by city