Wide-Area Monitoring and PMU Analytics Course

Connect synchronized measurements, PMU streams, data quality, visualization, oscillation analysis, and event evidence for grid decisions.
Wide-Area Monitoring and PMU Analytics Course

At a glance

Duration
2 Weeks
Format
Classroom
Cities
London, Trabzon, Marbella, Cape town, Sharm El-Sheikh, Amman and more
Next session
19 – 30 October 2026, London
Average fee
14,050 €

Overview

Advanced Wide-Area Monitoring and PMU Analytics Training Course is a two-week course for power system engineers, control-center analysts, protection and stability specialists, utility data engineers, and transmission operations managers who leave with a Wide-Area Monitoring and Analytics Pack. Participants connect synchronized measurement chains, PMU streams, phasor data concentrators, data quality, visualization, oscillation analysis, and event reconstruction. The course turns high-rate phasor data into governed operational evidence. Agile Leaders Training Center develops wide-area monitoring practice.

Who Should Attend

  • Power system functions responsible for transmission analysis, stability, and operating limits

  • Control-center functions responsible for situational awareness and event response

  • Protection functions responsible for disturbance evidence and coordinated schemes

  • Utility data functions responsible for PMU streams, concentrators, quality, and access

  • Operations management functions responsible for monitoring use cases and decision governance

The course assumes participants already interpret power-system quantities and operating diagrams; it leaves out PMU product certification, relay setting design, and software coding.

Departments and Industries

The course supports departments and industries that monitor and operate interconnected electric power systems.

  • Transmission operations, system planning, protection, automation, and control centers

  • Generation, renewable integration, interconnection, and grid-support functions

  • Utility data engineering, telecommunications, cybersecurity, and analytics functions

  • Engineering consultancies, equipment vendors, testing laboratories, and research organizations

  • Industrial power networks, transport electrification, and critical infrastructure operators

Learning Objectives

By the end of this course, participants will be able to:

  • Build a wide-area measurement architecture and data-flow map.

  • Apply IEEE C37.118.2-2024 messaging concepts and PMU data-quality controls.

  • Analyze phase angle, frequency, oscillation, and disturbance evidence.

  • Diagnose timing, coverage, consistency, and stream-availability problems.

  • Evaluate monitoring displays, alerts, and operational use cases.

  • Build a Wide-Area Monitoring and Analytics Pack.

Course Agenda

Day 1: Frame Wide-Area Monitoring

  • Wide-Area Monitoring Use-Case Canvas

  • Synchrophasor Measurement Chain Map

  • PMU, PDC, and Application Role Model

  • SCADA and Synchrophasor Comparison Matrix

  • Monitoring Decision and Evidence Register

Day 2: Examine PMU Measurements

  • Voltage and Current Phasor Representation Model

  • Frequency and Rate-of-Change Measure Dictionary

  • Time Synchronization and Timestamp Trace

  • PMU Reporting Rate and Latency Profile

  • Measurement Accuracy and Metadata Record

Day 3: Design Data Concentration

  • Phasor Data Concentrator Architecture Diagram

  • PMU Stream Aggregation and Alignment Method

  • Hierarchical PDC Routing and Redundancy Map

  • Communication Delay and Availability Budget

  • Source-to-Application Data Lineage View

Day 4: Apply Data Transfer Concepts

  • IEEE C37.118.2-2024 Message Structure Map

  • Configuration, Data, Header, and Command Frame Table

  • Data Type and Format Validation Checklist

  • Stream Interface and Protocol Boundary Matrix

  • PMU-to-PDC Interoperability Test Record

Day 5: Control Synchrophasor Quality

  • Accuracy, Availability, and Timeliness Scorecard

  • Coverage and Consistency Assessment Grid

  • Missing, Stale, and Outlier Data Diagnostic

  • Timestamp and Topology Alignment Checklist

  • Data Quality Exception and Remediation Log

Day 6: Build Monitoring Displays

  • Phase-Angle Difference Visualization Pattern

  • Frequency and ROCOF Trend Display

  • Voltage Magnitude and Corridor Stress View

  • PMU Stream Health and Quality Dashboard

  • Alert Threshold and Escalation Matrix

Day 7: Analyze Oscillations

  • Oscillation Detection Signal Review Method

  • Mode Frequency and Damping Evidence Table

  • Inter-Area Oscillation Location Map

  • Event Window and Baseline Comparison Profile

  • Oscillation Alert Confidence Record

Day 8: Reconstruct Grid Events

  • Disturbance Timeline Reconstruction Method

  • Phase-Angle Separation and Recovery Plot

  • Frequency Excursion and ROCOF Event Profile

  • Protection Operation and PMU Evidence Crosswalk

  • Post-Event Analysis Report Structure

Day 9: Govern Operational Use Cases

  • Wide-Area Monitoring Use-Case Priority Matrix

  • Display, Alert, and Decision Ownership Model

  • Data Retention and Access Requirement Register

  • Monitoring Limitation and Decision-Risk Log

  • Deployment and Operational Readiness Checklist

Day 10: Practice PMU Analytics Reviews

  • Exercise: Diagnose a PMU Stream Quality Issue

  • Exercise: Interpret a Phase-Angle Separation

  • Exercise: Analyze an Oscillation Event

  • Exercise: Reconstruct a Grid Disturbance

  • Capstone: Wide-Area Monitoring and Analytics Pack

Practical Exercises

The course uses suggested activities based on transmission corridors, generation events, renewable integration, and industrial-grid cases.

  • Suggested activity: trace synchronized measurements from PMUs through concentrators to an operational display.

  • Suggested activity: diagnose timing, availability, consistency, coverage, and metadata defects in a PMU stream.

  • Suggested activity: compare phase angle, frequency, damping, and disturbance evidence across an event window.

  • Suggested activity: present a monitoring use case with limits, thresholds, owners, and response actions.

FAQs

Who suits wide-area monitoring and PMU analytics training, and what does it assume?

Power system, control-center, protection, stability, utility data, and transmission operations functions suit the training. Wide-area monitoring assumes regular interpretation of power-system quantities and operating diagrams.

How does PMU analytics differ from conventional power-system monitoring training?

PMU analytics focuses on time-synchronized phasor streams, phase-angle relationships, high-rate frequency evidence, data concentrators, quality controls, oscillations, and event reconstruction, while conventional monitoring relies on slower and less synchronized operational measurements.

Why is IEEE C37.118.2-2024 relevant to PMU analytics?

IEEE C37.118.2-2024 defines messaging for real-time communication between PMUs, phasor data concentrators, and applications, providing the data-transfer structure that PMU analytics workflows must interpret.

How does PMU data quality affect wide-area monitoring?

PMU data quality affects whether phase angle, frequency, oscillation, and disturbance evidence can be trusted; accuracy, availability, timeliness, coverage, consistency, metadata, and stream paths must be assessed.

What does a wide-area monitoring review produce?

A wide-area monitoring review produces a documented interpretation of system conditions, data limitations, alerts, event evidence, operational implications, decision ownership, and follow-up actions.

Conclusion

Participants take back a Wide-Area Monitoring and Analytics Pack containing architecture maps, data-flow views, quality controls, display designs, oscillation records, event reconstructions, use-case priorities, and readiness checks. It changes raw PMU streams into governed operational evidence. The pack supports traceable monitoring, consistent reviews, and accountable grid decisions.

credits: 5 credit per day

Course Mode: full-time

Provider: Agile Leaders Training Center

Showing 41-56 of 56 events
Image Location Dates Duration Mode Price Actions
Casablanca Casablanca Week 29, 2027
19 – 30 July 2027
2 Weeks Onsite €12,000
Toronto Toronto Week 29, 2027
25 July – 5 August 2027
2 Weeks Onsite €20,000
Munich Munich Week 31, 2027
2 – 13 August 2027
2 Weeks Onsite €14,000
New York New York Week 31, 2027
2 – 13 August 2027
2 Weeks Onsite €20,000
Kuala Lumpur Kuala Lumpur Week 32, 2027
9 – 20 August 2027
2 Weeks Onsite €14,000
Baku Baku Week 33, 2027
16 – 27 August 2027
2 Weeks Onsite €15,000
Kuwait Kuwait Week 33, 2027
22 August – 2 September 2027
2 Weeks Onsite €14,000
Lisbon Lisbon Week 34, 2027
23 August – 3 September 2027
2 Weeks Onsite €14,000
Barcelona Barcelona Week 35, 2027
30 August – 10 September 2027
2 Weeks Onsite €14,000
Abu Dhabi Abu Dhabi Week 35, 2027
30 August – 10 September 2027
2 Weeks Onsite €14,000
Milan Milan Week 36, 2027
6 – 17 September 2027
2 Weeks Onsite €14,000
San Diego San Diego Week 37, 2027
13 – 24 September 2027
2 Weeks Onsite €16,000
Geneva Geneva Week 37, 2027
19 – 30 September 2027
2 Weeks Onsite €18,000
Dubai Dubai Week 39, 2027
27 September – 8 October 2027
2 Weeks Onsite €13,000
Montreux Montreux Week 40, 2027
4 – 15 October 2027
2 Weeks Onsite €18,000
Seoul Seoul Week 41, 2027
11 – 22 October 2027
2 Weeks Onsite €18,000

Frequently asked questions

What does this course cover?

OverviewAdvanced Wide-Area Monitoring and PMU Analytics Training Course is a two-week course for power system engineers, control-center analysts, protection and stability specialists, utility data engineers, and transmission operations managers who leave with a Wide-Area Monitoring and Analytics Pack. Participants connect synchronized measurement chains,…

Are training dates available?

Yes. Available dates and destinations are listed in the course dates section on this page.

How can I register?

Choose an available date on this page and complete the registration form, or send a programme enquiry.

Can I download the course brochure?

Yes. Use the brochure download link provided on this page.

This course by city