Applied Gas Chromatography Operations and Troubleshooting Training Course
Course Details
-
# 1938_243863
-
1 – 5 November 2027 05.Nov.2027
-
Zoom
-
3000 €
Overview
Applied Gas Chromatography Operations and Troubleshooting Training Course is a one-week advanced course for analytical chemists, laboratory analysts, technicians, instrument specialists, and laboratory supervisors who leave with a Gas Chromatography Method and Troubleshooting File. Participants connect gas chromatography operations, representative sampling, separation settings, chromatographic method calibration, natural gas composition analysis, GC data integrity, and gas chromatography troubleshooting. The course uses diagnostic records and controlled method decisions to improve result reliability. Agile Leaders Training Center presents applied gas chromatography practice.
Who Should Attend
- Laboratory functions responsible for gas and volatile-liquid sample analysis
- Quality-control functions responsible for calibration, result review, and method performance
- Technical functions responsible for GC operation, maintenance, and fault response
- Process-support functions responsible for refinery, gas-processing, and petrochemical data
- Supervisory functions responsible for laboratory reliability and data integrity
The course assumes participants already follow laboratory procedures and interpret basic chromatograms, and it leaves out HPLC operation, instrument board repair, and formal method-approval authority.
Departments and Industries
The course supports departments and industries that depend on traceable gas-phase separation and measurement.
- Oil and gas production, processing, and transmission laboratories
- Refining, petrochemical, and chemical manufacturing
- Environmental monitoring and industrial hygiene laboratories
- Quality control and analytical development
- Instrument engineering and laboratory maintenance
Learning Objectives
By the end of this course, participants will be able to:
- Apply representative sampling and sample-conditioning controls
- Compare injectors, carrier gases, columns, and detectors
- Build calibration and quantitative-analysis records
- Analyze retention, resolution, baseline, and peak behavior
- Diagnose leaks, contamination, carryover, and performance drift
- Evaluate maintenance, uncertainty, safety, and data integrity
Course Agenda
Day 1: Control Samples and Flow Paths
- Representative Gas Sampling and Conditioning Checklist
- Sample Container, Transfer Line, and Loop Selection Matrix
- Carrier Gas Purity and Pressure-Control Record
- Leak Testing and Flow-Path Integrity Method
- GC Safety Hazard and Control Register
Day 2: Configure Separation and Detection
- Split, Splitless, Gas-Valve, and Headspace Injection Map
- Packed and Capillary Column Selection Matrix
- Stationary-Phase Polarity and Selectivity Guide
- Isothermal and Temperature-Program Design Sheet
- FID, TCD, and Detector Selection Framework
Day 3: Calibrate and Quantify Results
- Reference Standard and Calibration-Gas Control Log
- External, Internal, and Area-Normalization Calibration Method
- Retention-Time Identification and Peak Assignment Table
- Response Factor and Quantitative Calculation Sheet
- Method Performance, Uncertainty, and Traceability Record
Day 4: Diagnose and Maintain GC Performance
- Baseline Noise, Drift, and Contamination Decision Tree
- Retention Shift and Resolution-Loss Diagnostic Matrix
- Peak Tailing, Fronting, and Broadening Fault Guide
- Carryover, Ghost Peak, and Detector Response Checklist
- Preventive Maintenance and Return-to-Service Plan
Day 5: Practice GC Reliability
- Suggested Exercise: Verify Sampling and Flow-Path Controls
- Suggested Exercise: Select Column, Program, and Detector Settings
- Suggested Exercise: Calculate Calibration and Sample Results
- Suggested Exercise: Diagnose a Chromatogram Fault Set
- Capstone Exercise: Complete the Gas Chromatography Method and Troubleshooting File
Practical Exercises
The course uses suggested activities to convert chromatograms, instrument observations, and quality records into controlled analytical decisions.
- Suggested activity: assess a gas-sampling route for condensation, contamination, leakage, and representativeness.
- Suggested activity: select an injector, column, temperature program, and detector for a defined analyte mixture.
- Suggested activity: build a calibration record and test quantitative results for traceability and uncertainty.
- Suggested activity: isolate baseline, retention, peak-shape, carryover, and response faults from evidence.
FAQs
Who suits applied gas chromatography training, and what does it assume?
Applied gas chromatography training suits analytical, quality-control, instrument, process-support, and laboratory-supervision functions. It assumes participants already use laboratory procedures and interpret basic chromatograms.
How does gas chromatography training differ from HPLC training?
Gas chromatography training focuses on volatile analytes moved by a carrier gas through GC columns and detected with gas-phase instrumentation. HPLC training focuses on liquid mobile phases, pumps, solvent systems, and liquid-chromatography hardware.
How should gas chromatography troubleshooting begin?
Gas chromatography troubleshooting should begin by defining the symptom, reviewing recent changes, checking gases and flow paths, testing for leaks, examining blanks and standards, and isolating one variable at a time.
What supports reliable natural gas composition analysis by GC?
Reliable natural gas composition analysis depends on representative sampling, controlled pressure and temperature, suitable columns and detectors, traceable calibration gases, correct peak identification, documented calculations, and performance checks.
Conclusion
Participants take back a Gas Chromatography Method and Troubleshooting File linking sample controls, instrument settings, calibration, calculations, diagnostics, maintenance, and data-quality evidence. It changes disconnected operating notes into one traceable analytical record. The file supports method review, fault response, result approval, and reliability planning.
Oil & Gas Training and Other Technical Courses
Gas Chromatography Operations and Troubleshooting Course (1938_243863)
Course Details
# 1938_243863
1 – 5 November 2027
Zoom
Fees : 3000 €
Applied Gas Chromatography Operations and Troubleshooting Training Course runs in Zoom over 5 days, with 1 upcoming date in Zoom. The course fee is 3,000 €.
All dates in Zoom
| Dates | Price | Actions |
|---|---|---|
| 1 – 5 November 2027 | 3,000 € | Register |
Training in Zoom
If you can't make it to one of our physical locations, we also offer a wide range of professional training courses on demand through online coaching meetings.
All courses in ZoomThis course in other cities
- Abu Dhabi
- Accra
- Addis Ababa
- Amman
- Amsterdam
- Athens
- Baku
- Bali
- Bangkok
- Barcelona
- Berlin
- Cairo
- Cape town
- Casablanca
- Chicago
- Doha
- Dubai
- Frankfurt
- Geneva
- Istanbul
- Jakarta
- Johannesburg
- Kuala Lumpur
- Kuwait
- Lagos
- Langkawi
- Lisbon
- London
- Madrid
- Manama
- Marbella
- Milan
- Montreux
- Munich
- Muscat
- Nairobi
- New York
- Nice
- Paris
- Phuket
- Porto
- Prague
- Rome
- San Diego
- Seoul
- Sharm El-Sheikh
- Singapore
- Tashkent
- Tbilisi
- Tokyo
- Toronto
- Trabzon
- Vienna
- Zanzibar