Gas Chromatography Operations and Troubleshooting Course

Operate gas chromatography systems, control analytical performance, diagnose faults, and document reliable results.
Gas Chromatography Operations and Troubleshooting Course

At a glance

Duration
1 Week
Format
Classroom
Cities
Sharm El-Sheikh, Singapore, Abu Dhabi, Dubai, Lisbon, Athens and more
Next session
9 – 13 November 2026, Sharm El-Sheikh
Average fee
7,500 €

Overview

Applied Gas Chromatography Operations and Troubleshooting Training Course is a one-week advanced course for analytical chemists, laboratory analysts, technicians, instrument specialists, and laboratory supervisors who leave with a Gas Chromatography Method and Troubleshooting File. Participants connect gas chromatography operations, representative sampling, separation settings, chromatographic method calibration, natural gas composition analysis, GC data integrity, and gas chromatography troubleshooting. The course uses diagnostic records and controlled method decisions to improve result reliability. Agile Leaders Training Center presents applied gas chromatography practice.

Who Should Attend

  • Laboratory functions responsible for gas and volatile-liquid sample analysis
  • Quality-control functions responsible for calibration, result review, and method performance
  • Technical functions responsible for GC operation, maintenance, and fault response
  • Process-support functions responsible for refinery, gas-processing, and petrochemical data
  • Supervisory functions responsible for laboratory reliability and data integrity

The course assumes participants already follow laboratory procedures and interpret basic chromatograms, and it leaves out HPLC operation, instrument board repair, and formal method-approval authority.

Departments and Industries

The course supports departments and industries that depend on traceable gas-phase separation and measurement.

  • Oil and gas production, processing, and transmission laboratories
  • Refining, petrochemical, and chemical manufacturing
  • Environmental monitoring and industrial hygiene laboratories
  • Quality control and analytical development
  • Instrument engineering and laboratory maintenance

Learning Objectives

By the end of this course, participants will be able to:

  • Apply representative sampling and sample-conditioning controls
  • Compare injectors, carrier gases, columns, and detectors
  • Build calibration and quantitative-analysis records
  • Analyze retention, resolution, baseline, and peak behavior
  • Diagnose leaks, contamination, carryover, and performance drift
  • Evaluate maintenance, uncertainty, safety, and data integrity

Course Agenda

Day 1: Control Samples and Flow Paths

  • Representative Gas Sampling and Conditioning Checklist
  • Sample Container, Transfer Line, and Loop Selection Matrix
  • Carrier Gas Purity and Pressure-Control Record
  • Leak Testing and Flow-Path Integrity Method
  • GC Safety Hazard and Control Register

Day 2: Configure Separation and Detection

  • Split, Splitless, Gas-Valve, and Headspace Injection Map
  • Packed and Capillary Column Selection Matrix
  • Stationary-Phase Polarity and Selectivity Guide
  • Isothermal and Temperature-Program Design Sheet
  • FID, TCD, and Detector Selection Framework

Day 3: Calibrate and Quantify Results

  • Reference Standard and Calibration-Gas Control Log
  • External, Internal, and Area-Normalization Calibration Method
  • Retention-Time Identification and Peak Assignment Table
  • Response Factor and Quantitative Calculation Sheet
  • Method Performance, Uncertainty, and Traceability Record

Day 4: Diagnose and Maintain GC Performance

  • Baseline Noise, Drift, and Contamination Decision Tree
  • Retention Shift and Resolution-Loss Diagnostic Matrix
  • Peak Tailing, Fronting, and Broadening Fault Guide
  • Carryover, Ghost Peak, and Detector Response Checklist
  • Preventive Maintenance and Return-to-Service Plan

Day 5: Practice GC Reliability

  • Suggested Exercise: Verify Sampling and Flow-Path Controls
  • Suggested Exercise: Select Column, Program, and Detector Settings
  • Suggested Exercise: Calculate Calibration and Sample Results
  • Suggested Exercise: Diagnose a Chromatogram Fault Set
  • Capstone Exercise: Complete the Gas Chromatography Method and Troubleshooting File

Practical Exercises

The course uses suggested activities to convert chromatograms, instrument observations, and quality records into controlled analytical decisions.

  • Suggested activity: assess a gas-sampling route for condensation, contamination, leakage, and representativeness.
  • Suggested activity: select an injector, column, temperature program, and detector for a defined analyte mixture.
  • Suggested activity: build a calibration record and test quantitative results for traceability and uncertainty.
  • Suggested activity: isolate baseline, retention, peak-shape, carryover, and response faults from evidence.

FAQs

Who suits applied gas chromatography training, and what does it assume?

Applied gas chromatography training suits analytical, quality-control, instrument, process-support, and laboratory-supervision functions. It assumes participants already use laboratory procedures and interpret basic chromatograms.

How does gas chromatography training differ from HPLC training?

Gas chromatography training focuses on volatile analytes moved by a carrier gas through GC columns and detected with gas-phase instrumentation. HPLC training focuses on liquid mobile phases, pumps, solvent systems, and liquid-chromatography hardware.

How should gas chromatography troubleshooting begin?

Gas chromatography troubleshooting should begin by defining the symptom, reviewing recent changes, checking gases and flow paths, testing for leaks, examining blanks and standards, and isolating one variable at a time.

What supports reliable natural gas composition analysis by GC?

Reliable natural gas composition analysis depends on representative sampling, controlled pressure and temperature, suitable columns and detectors, traceable calibration gases, correct peak identification, documented calculations, and performance checks.

Conclusion

Participants take back a Gas Chromatography Method and Troubleshooting File linking sample controls, instrument settings, calibration, calculations, diagnostics, maintenance, and data-quality evidence. It changes disconnected operating notes into one traceable analytical record. The file supports method review, fault response, result approval, and reliability planning.

credits: 5 credit per day

Course Mode: full-time

Provider: Agile Leaders Training Center

Showing 1-20 of 58 events
Image Location Dates Duration Mode Price Actions
Sharm El-Sheikh Sharm El-Sheikh Week 46, 2026
9 – 13 November 2026
1 Week Onsite €5,200
Singapore Singapore Week 46, 2026
9 – 13 November 2026
1 Week Onsite €6,500
Abu Dhabi Abu Dhabi Week 47, 2026
16 – 20 November 2026
1 Week Onsite €6,500
Dubai Dubai Week 48, 2026
23 – 27 November 2026
1 Week Onsite €6,500
Lisbon Lisbon Week 48, 2026
23 – 27 November 2026
1 Week Onsite €6,500
Athens Athens Week 49, 2026
30 November – 4 December 2026
1 Week Onsite €7,500
Munich Munich Week 50, 2026
7 – 11 December 2026
1 Week Onsite €6,500
Toronto Toronto Week 50, 2026
13 – 17 December 2026
1 Week Onsite €16,000
Bali Bali Week 51, 2026
20 – 24 December 2026
1 Week Onsite €6,500
Nice Nice Week 53, 2026
28 December 2026 – 1 January 2027
1 Week Onsite €8,000
Tokyo Tokyo Week 01, 2027
4 – 8 January 2027
1 Week Onsite €12,000
Frankfurt Frankfurt Week 01, 2027
4 – 8 January 2027
1 Week Onsite €6,500
San Diego San Diego Week 02, 2027
11 – 15 January 2027
1 Week Onsite €16,000
Jakarta Jakarta Week 03, 2027
18 – 22 January 2027
1 Week Onsite €8,000
Geneva Geneva Week 03, 2027
24 – 28 January 2027
1 Week Onsite €8,000
Porto Porto Week 04, 2027
25 – 29 January 2027
1 Week Onsite €6,500
Kuwait Kuwait Week 04, 2027
31 January – 4 February 2027
1 Week Onsite €7,000
Seoul Seoul Week 06, 2027
8 – 12 February 2027
1 Week Onsite €12,000
Montreux Montreux Week 07, 2027
15 – 19 February 2027
1 Week Onsite €8,000
London London Week 08, 2027
22 – 26 February 2027
1 Week Onsite €6,500

Frequently asked questions

What does this course cover?

OverviewApplied Gas Chromatography Operations and Troubleshooting Training Course is a one-week advanced course for analytical chemists, laboratory analysts, technicians, instrument specialists, and laboratory supervisors who leave with a Gas Chromatography Method and Troubleshooting File. Participants connect gas chromatography operations, representative…

Are training dates available?

Yes. Available dates and destinations are listed in the course dates section on this page.

How can I register?

Choose an available date on this page and complete the registration form, or send a programme enquiry.

Can I download the course brochure?

Yes. Use the brochure download link provided on this page.

This course by city