Gas Chromatography Operations and Troubleshooting Course

Operate gas chromatography systems, control analytical performance, diagnose faults, and document reliable results.
Gas Chromatography Operations and Troubleshooting Course

At a glance

Duration
1 Week
Format
Classroom
Cities
Sharm El-Sheikh, Singapore, Abu Dhabi, Dubai, Lisbon, Athens and more
Next session
9 – 13 November 2026, Sharm El-Sheikh
Average fee
7,500 €

Overview

Applied Gas Chromatography Operations and Troubleshooting Training Course is a one-week advanced course for analytical chemists, laboratory analysts, technicians, instrument specialists, and laboratory supervisors who leave with a Gas Chromatography Method and Troubleshooting File. Participants connect gas chromatography operations, representative sampling, separation settings, chromatographic method calibration, natural gas composition analysis, GC data integrity, and gas chromatography troubleshooting. The course uses diagnostic records and controlled method decisions to improve result reliability. Agile Leaders Training Center presents applied gas chromatography practice.

Who Should Attend

  • Laboratory functions responsible for gas and volatile-liquid sample analysis
  • Quality-control functions responsible for calibration, result review, and method performance
  • Technical functions responsible for GC operation, maintenance, and fault response
  • Process-support functions responsible for refinery, gas-processing, and petrochemical data
  • Supervisory functions responsible for laboratory reliability and data integrity

The course assumes participants already follow laboratory procedures and interpret basic chromatograms, and it leaves out HPLC operation, instrument board repair, and formal method-approval authority.

Departments and Industries

The course supports departments and industries that depend on traceable gas-phase separation and measurement.

  • Oil and gas production, processing, and transmission laboratories
  • Refining, petrochemical, and chemical manufacturing
  • Environmental monitoring and industrial hygiene laboratories
  • Quality control and analytical development
  • Instrument engineering and laboratory maintenance

Learning Objectives

By the end of this course, participants will be able to:

  • Apply representative sampling and sample-conditioning controls
  • Compare injectors, carrier gases, columns, and detectors
  • Build calibration and quantitative-analysis records
  • Analyze retention, resolution, baseline, and peak behavior
  • Diagnose leaks, contamination, carryover, and performance drift
  • Evaluate maintenance, uncertainty, safety, and data integrity

Course Agenda

Day 1: Control Samples and Flow Paths

  • Representative Gas Sampling and Conditioning Checklist
  • Sample Container, Transfer Line, and Loop Selection Matrix
  • Carrier Gas Purity and Pressure-Control Record
  • Leak Testing and Flow-Path Integrity Method
  • GC Safety Hazard and Control Register

Day 2: Configure Separation and Detection

  • Split, Splitless, Gas-Valve, and Headspace Injection Map
  • Packed and Capillary Column Selection Matrix
  • Stationary-Phase Polarity and Selectivity Guide
  • Isothermal and Temperature-Program Design Sheet
  • FID, TCD, and Detector Selection Framework

Day 3: Calibrate and Quantify Results

  • Reference Standard and Calibration-Gas Control Log
  • External, Internal, and Area-Normalization Calibration Method
  • Retention-Time Identification and Peak Assignment Table
  • Response Factor and Quantitative Calculation Sheet
  • Method Performance, Uncertainty, and Traceability Record

Day 4: Diagnose and Maintain GC Performance

  • Baseline Noise, Drift, and Contamination Decision Tree
  • Retention Shift and Resolution-Loss Diagnostic Matrix
  • Peak Tailing, Fronting, and Broadening Fault Guide
  • Carryover, Ghost Peak, and Detector Response Checklist
  • Preventive Maintenance and Return-to-Service Plan

Day 5: Practice GC Reliability

  • Suggested Exercise: Verify Sampling and Flow-Path Controls
  • Suggested Exercise: Select Column, Program, and Detector Settings
  • Suggested Exercise: Calculate Calibration and Sample Results
  • Suggested Exercise: Diagnose a Chromatogram Fault Set
  • Capstone Exercise: Complete the Gas Chromatography Method and Troubleshooting File

Practical Exercises

The course uses suggested activities to convert chromatograms, instrument observations, and quality records into controlled analytical decisions.

  • Suggested activity: assess a gas-sampling route for condensation, contamination, leakage, and representativeness.
  • Suggested activity: select an injector, column, temperature program, and detector for a defined analyte mixture.
  • Suggested activity: build a calibration record and test quantitative results for traceability and uncertainty.
  • Suggested activity: isolate baseline, retention, peak-shape, carryover, and response faults from evidence.

FAQs

Who suits applied gas chromatography training, and what does it assume?

Applied gas chromatography training suits analytical, quality-control, instrument, process-support, and laboratory-supervision functions. It assumes participants already use laboratory procedures and interpret basic chromatograms.

How does gas chromatography training differ from HPLC training?

Gas chromatography training focuses on volatile analytes moved by a carrier gas through GC columns and detected with gas-phase instrumentation. HPLC training focuses on liquid mobile phases, pumps, solvent systems, and liquid-chromatography hardware.

How should gas chromatography troubleshooting begin?

Gas chromatography troubleshooting should begin by defining the symptom, reviewing recent changes, checking gases and flow paths, testing for leaks, examining blanks and standards, and isolating one variable at a time.

What supports reliable natural gas composition analysis by GC?

Reliable natural gas composition analysis depends on representative sampling, controlled pressure and temperature, suitable columns and detectors, traceable calibration gases, correct peak identification, documented calculations, and performance checks.

Conclusion

Participants take back a Gas Chromatography Method and Troubleshooting File linking sample controls, instrument settings, calibration, calculations, diagnostics, maintenance, and data-quality evidence. It changes disconnected operating notes into one traceable analytical record. The file supports method review, fault response, result approval, and reliability planning.

credits: 5 credit per day

Course Mode: full-time

Provider: Agile Leaders Training Center

Showing 21-40 of 58 events
Image Location Dates Duration Mode Price Actions
Trabzon Trabzon Week 08, 2027
28 February – 4 March 2027
1 Week Onsite €8,000
Milan Milan Week 10, 2027
8 – 12 March 2027
1 Week Onsite €7,000
Paris Paris Week 11, 2027
15 – 19 March 2027
1 Week Onsite €6,500
Prague Prague Week 13, 2027
29 March – 2 April 2027
1 Week Onsite €7,500
Abu Dhabi Abu Dhabi Week 13, 2027
29 March – 2 April 2027
1 Week Onsite €6,500
Vienna Vienna Week 15, 2027
12 – 16 April 2027
1 Week Onsite €7,500
Phuket Phuket Week 15, 2027
18 – 22 April 2027
1 Week Onsite €8,000
Madrid Madrid Week 17, 2027
26 – 30 April 2027
1 Week Onsite €6,500
Accra Accra Week 17, 2027
2 – 6 May 2027
1 Week Onsite €6,000
Zanzibar Zanzibar Week 18, 2027
9 – 13 May 2027
1 Week Onsite €6,000
Kuala Lumpur Kuala Lumpur Week 20, 2027
17 – 21 May 2027
1 Week Onsite €6,500
Muscat Muscat Week 20, 2027
23 – 27 May 2027
1 Week Onsite €6,500
Doha Doha Week 21, 2027
30 May – 3 June 2027
1 Week Onsite €7,000
Lagos Lagos Week 21, 2027
30 May – 3 June 2027
1 Week Onsite €6,000
Tbilisi Tbilisi Week 23, 2027
7 – 11 June 2027
1 Week Onsite €5,700
Casablanca Casablanca Week 24, 2027
14 – 18 June 2027
1 Week Onsite €6,000
Dubai Dubai Week 25, 2027
21 – 25 June 2027
1 Week Onsite €6,500
Nairobi Nairobi Week 25, 2027
27 June – 1 July 2027
1 Week Onsite €6,000
Berlin Berlin Week 26, 2027
28 June – 2 July 2027
1 Week Onsite €6,500
Langkawi Langkawi Week 26, 2027
4 – 8 July 2027
1 Week Onsite €8,000

Frequently asked questions

What does this course cover?

OverviewApplied Gas Chromatography Operations and Troubleshooting Training Course is a one-week advanced course for analytical chemists, laboratory analysts, technicians, instrument specialists, and laboratory supervisors who leave with a Gas Chromatography Method and Troubleshooting File. Participants connect gas chromatography operations, representative…

Are training dates available?

Yes. Available dates and destinations are listed in the course dates section on this page.

How can I register?

Choose an available date on this page and complete the registration form, or send a programme enquiry.

Can I download the course brochure?

Yes. Use the brochure download link provided on this page.

This course by city